ESU15
0 Tubes in archive
BrandEDISWAN
ClassHalf Wave Mercury Vapour Rectifier
Construction
Primary TypeRectifier
Rectifier TypeHalf Wave
Filament / Heater
Warm-up Time60s
Absolute Maximum Ratings
Plate Voltage20000 V
Cathode Current3000 mA
Audio Performance
Key Features
- Directly heated
- Mercury vapour type
- Inverted operation
Application Notes
The ESU15 must be operated in an inverted position. When operating above 10 kV P.I.V., cooling must be used to maintain a condensed mercury temperature below 60°C (40°C recommended). On first use, the filament must run for 15 minutes before applying H.T. Thereafter, a delay of at least 60 seconds is required before applying H.T.
Datasheet Viewer
Loading datasheet...
Sort by
Showing 1 to 0 of 0 results