Tube-number record
MV6-5
0 archive entries
BrandPhilips
ClassRadar Cathode-Ray Projection Tube
BaseSpecial / none
Filament6.3 V @ 300 mA
Construction
Primary TypeDisplay / CRT
EnvelopeGlass
SectionsSingle
Filament / Heater
Heater NotesIndirect by A.C. or D.C.
Absolute Maximum Ratings
Plate Voltage27000 V
Grid 1 Voltage-200 V
Cathode Current0.2 mA
H-C Voltage125 V
Audio Performance
Key Features
- Magnetic focusing
- Magnetic deflection
- Indirect heating
- X-ray radiation shielding required
Typical Operation
| Mode | Plate V | Gm (µmhos) | Rp (Ω) | µ | Plate mA |
|---|---|---|---|---|---|
| Magnetic Focus/Deflection | 25000 V | — | — | — | 0.001 mA |
Application Notes
An X-ray radiation shielding with an equivalent lead thickness of 0.5 mm is required to protect the observer. Measures should be taken for the beam current to be switched off immediately if time-base circuits fail.