Tube-number record
EHT 15
0 archive entries
BrandEDISWAN RADIO
ClassMercury Vapour Rectifier
BaseScrew / Edison base
Construction
Primary TypeRectifier
Rectifier TypeMercury Vapour
EnvelopeGlass
SectionsSingle
Filament / Heater
MaterialHot mercury vapour type
Warm-up Time60s
Absolute Maximum Ratings
Plate Voltage30000 V
Cathode Current4500 mA
Audio Performance
Key Features
- High voltage half-wave rectifier
- Low and constant voltage drop
- High efficiency
- Long and efficient service
Application Notes
The cathode must reach full operating temperature before H.T. voltage is applied to the anode, requiring a delay of at least one minute. When switching off, disconnect the H.T. supply before the cathode supply. Operating temperature should never exceed 40°C; forced air cooling from a fan may be necessary in warm environments. An anode fuse should be mounted as close to the cap as possible.
Datasheets
Datasheet: EHT15.pdf
Download PDFLoading datasheet...
Datasheets courtesy of Frank Philipse via Frank's Electron Tube Data Sheets.