D14-240
0 Tubes in archive
BrandPhilips
ClassCathode Ray Tube
Construction
Primary TypePDA (Post Deflection Acceleration)
EnvelopeGlass
SectionsSingle beam
Filament / Heater
Absolute Maximum Ratings
Plate Voltage20000 V
Audio Performance
Key Features
- 20 kV PDA tube
- Internal graticule
- High writing rate
- Minimum length for portability
- Large screen display
Typical Operation
| Mode | Plate V | Gm (µmhos) | Rp (Ω) | µ | Plate mA |
|---|---|---|---|---|---|
| Oscilloscope Display | 20000V | - | 1000000 | - | - |
Application Notes
Specifically developed for the Philips PM 3260 lightweight portable 120 MHz oscilloscope.