15J12
0 Tubes in archive
BrandEdiswan
ClassForced Air Cooled Triode
BaseSpecial
Construction
Primary TypeTriode
EnvelopeExternal Anode
Base MaterialSpecial
Sections1
Filament / Heater
MaterialThoriated Tungsten
Absolute Maximum Ratings
Plate Voltage7000 V
Plate Dissipation4300 W
Cathode Current40000 mA
Audio Performance
Power Output900 W
Key Features
- Forced air cooled
- Directly heated
- Thoriated tungsten filament
- External Anode
Typical Operation
| Mode | Plate V | Gm (µmhos) | Rp (Ω) | µ | Plate mA |
|---|---|---|---|---|---|
| Class C (3-phase/DC) | 4000V | 5100 | 4313.7 | 22 | 1068mA |
| Class C (3-phase/DC) | 5000V | 5100 | 4313.7 | 22 | 993mA |
| Class C (3-phase/DC) | 6000V | 5100 | 4313.7 | 22 | 930mA |
Application Notes
Intended for use in r.f. heating equipment. Connection should be made to both grid pins when running at higher frequencies. Minimum forced air blast of 60 cu.ft/min required.