0 Tubes in archive

BrandMarconi
ClassTransmitting Triode

Construction

Primary Typetriode
EnvelopeForced-air-cooled
Sections1

Filament / Heater

Materialtungsten

Absolute Maximum Ratings

Plate Voltage15000 V
Plate Dissipation20000 W

Audio Performance

Key Features
  • Forced-air-cooled
  • Tungsten filament
  • External grid and filament seal cooling required

Typical Operation

ModePlate VGm (µmhos)Rp (Ω)µPlate mA
HF Amplifier/Oscillator6000V--432000mA
HF Amplifier/Oscillator10000V35000--1500mA

Application Notes

The anode requires forced air cooling; temperature must not exceed 180°C. Grid and filament seals require approx 20 cu. ft. per minute air flow; seal temperature must not exceed 140°C. Air cooling supplies must be operational before applying supply voltages and continue for one minute after removal.